Connect Omni Editions: Web, Desktop & Embedded
Connect Omni is available in three editions, depending on where you want to run your Stage and connect your apps and devices.
Your apps continue running in their own environments. Connect Omni provides the shared space where they exchange messages and can be tested together.
Choose an edition
Edition | Best for |
|---|---|
Web | Cloud Stages for teams working across networks and locations |
Desktop | Local testing, hardware integrations, and access to Cloud Stages |
Embedded | Running a Local Stage server on a dedicated machine or restricted network |
Feature comparison
Capability | Web | Desktop | Embedded |
|---|---|---|---|
Cloud Stages | โ | โ | โ |
Local Stages | โ | โ | โ |
Adapter messaging | โ | โ | โ |
Web View and Adapter Stream | โ | โ | โ |
Plugins | โ | โ | โ |
Local | โ | โ | โ |
Host Figma prototypes | โ | โ | โ |
Plugins can also be used with Cloud Stages opened in Desktop. Local .pie files are supported only in Local Stages.
Embedded is a server edition. It isnโt related to the Embeds section of the Add Layer menu.
Connect Omni Desktop
Connect Omni Desktop is the macOS and Windows application for working with Local Stages, connecting hardware through Plugins, and testing apps on your computer or local network.
You can also open Cloud Stages from your Connect Omni organization.
Download and install
Direct downloads: macOS / Windows
Download and install Connect Omni Desktop.
Launch the application.
Sign in to your organizationโs Connect Omni environment to open Cloud Stages, or create a Local Stage.

Installing Desktop doesnโt automatically connect your apps. Use an Adapter, Web View, or Plugin depending on what you want to connect.
Connect apps on other computers
By default, Desktop accepts Adapter connections from the same computer only.
To allow connections from other computers or devices:
Open Settings โ General โ Network โ Server.
Select Local network. The change takes effect immediately, and Desktop restarts automatically.
Make sure the other devices can reach your computer and that your firewall allows the connection.
Note: The Apply & restart button appears only when changing the port number.

Connect Omni Embedded
Connect Omni Embedded runs a Local Stage server on a computer in your own network, without requiring the Desktop application.
Use it for labs, test benches, connected devices, or environments where you want a dedicated machine to host your testing environment.
Apps connect through Adapters, supported devices and services through Plugins, and participants can access the Stage from a browser.
Before you begin
Youโll need:
A computer or server running a supported operating system
A valid Connect Omni Embedded license for that device
Network access between the server and your connected apps or devices
The host computer must remain running while you use its Stages.
Download Connect Omni Embedded
Download Connect Omni Embedded
Or choose a platform:
Platform | Download |
|---|---|
Linux x64 | |
Linux ARM64 | |
macOS Apple Silicon | |
macOS Intel | |
Windows x64 |
Some platform builds may not be available in every release.
Install and run Embedded
Download and install the package for your operating system.
Register the Connect Omni Embedded
.licfile issued for your device.Start Connect Omni Embedded using the executable included in your installation.
Open
http://localhost:9988in a browser on the host computer.Create a Local Stage and connect your apps or devices using Adapters or Plugins.
Connect Omni Embedded follows the same general installation and startup process as ProtoPie Connect Embedded, with Connect Omni-specific files and executable names.
A valid Connect Omni Embedded license is required to start the server. Licenses are issued for a specific device and canโt be shared between Desktop and Embedded.
Access Embedded from another computer
To open the Stage from another device, use the Embedded host computerโs network address and configured server port.
Make sure:
The Embedded server is running.
Both devices can communicate over the network.
The firewall allows connections to the server.
The applications use valid Adapter Keys for the intended Stage.
Network and ports
Service | Default port |
|---|---|
Embedded Stage server |
|
Internal web UI and engine assets |
|
Built-in MQTT Broker |
|
These are default values and may differ depending on your installation.
The default local access address is http://localhost:9988. Use the Embedded hostโs network address when connecting from another computer.
Updates
Connect Omni Embedded checks for updates automatically.
If an update is required, the browser may restrict access to management features until the server operator updates the Embedded installation.
Contact the person managing your Embedded server to install the required version.
Troubleshooting
Embedded doesnโt start
Check that the Connect Omni Embedded license is valid and registered for the current device.
Canโt open Embedded in a browser
Check that the server is running and that youโre using the correct address and port. The default local address is http://localhost:9988.
Canโt access the Stage from another computer
Check the serverโs network address, network connectivity, and firewall settings.
An app canโt connect
Verify the Adapter Key, Stage Session, and network access. Use Backstage and Console to investigate the connection.
Licenses
Where you test | What you need |
|---|---|
Cloud Stages | Connect Omni account and organization access |
Desktop Local Stages | Connect Omni Desktop license for the device |
Embedded Local Stages | Connect Omni Embedded license for the device |
Desktop and Embedded licenses are separate. ProtoPie Connect licenses cannot be used with Connect Omni.
A local license doesnโt unlock Cloud Stages, and Cloud sign-in doesnโt activate a Local Stage license.